5-6 Head Replacement
Chapter 5 Maintenance and Adjustment
How to Replace the Head
MPX-90 Head Manager is used for the head replacement operation.
The pattern shown in the gure is struck during the head replacement operation. You need to prepare a test
print material (brass), which is supplied with a replacement head (MPH-90), or a material equal to or larger
than 60 mm (2.3 in.) x 60 mm (2.3 in.).
A replacement head is sold separately. Consult your authorized Roland DG Corp. dealer.
Do not stop the replacement operation halfway.
Do not use the head of which the marking pin is worn out.
Do not use the head which is detached from the machine.
Procedure
From [Start] menu, click [All Programs] (or [Programs]) → [MPX-90 Head Manager] →
[MPX-90 Head Manager].
MPX-90 Head Manager starts.
Switch on the power to the machine.
P. 30, "Switching On the Power"
Click [Readjust Pin].
Follow the on-screen instructions to
perform adjustment for the pin.
Set material using the adhesive sheet
and table.
P. 36, "Loading Material Using the Adhesive
Sheet"
Print the adjustment pattern using the
head cap.
P. 36, "Loading Material Using the Adhesive
Sheet"
If the adjustment pattern fails to be
printed, see the sections given below.
P. 104, "The printed location isn't where
desired," p. 105, "Striking is performed, but
nothing is printed"