S-4000 Digital Snake Owner’s Manual 95
Appendices
Specifications: S-4000H 32x8 FOH UNIT
Number of Channels:
8 in, 32 out
AD Conversion:
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
DA Conversion:
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Frequency Response:
-2 dB / +0 dB
(20 Hz to 20 kHz at +4 dBu)
Total Harmonic Distortion + Noise
(Input gain: +4 dBu, 22 ~ 20000 Hz):
0.05 % or less
Dynamic Range:
110 dB
Cross Talk:
-80 dB
Nominal Input Level:
+4 dBu, Max. +22 dBu
Input Impedance:
30 k ohms
Nominal Output Level:
+4 dBu, Max. +22 dBu
Output Impedance:
600 ohms
Recommended Load Impedance:
10 k ohm or greater
Residual Noise Level (IHF-A, typ.):
-92 dBu
Network Latency:
375 microseconds when using REAC cable only*
(AD REAC DA latency: about 1.2 milliseconds)
Connectors
Input: 1 (D-sub 25-pin connector, balanced, 8
channels)
Output: 4 (D-sub 25-pin connectors, balanced, 8
channels each)
REAC: MAIN, BACKUP
(RJ-45 EtherCon-type)
Remote Connector: 1
(RS-232C, DB-9-type)
MIDI Connectors: IN, OUT
(5-pin DIN-type)
Indicators:
EXT Indicator (External power supply)
INT Indicator
REAC Indicator
CTRL Indicator
ALARM Indicator
MUTE ALL OUTPUTS Indicator
Power Supply:
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240
V (50/60 Hz)
Power Supply (for optional power supply;
Model S-240P):
+24 V DC
Power Consumption:
70 W
Current Draw (for optional power supply;
Model S-240P):
6 A
* When a switching hub is used in-line with REAC cables, the network latency will increase by the amount of
processing delay introduced by the hub itself. The actual delay is dependant upon the specifications of the
hub, though the maximum delay amount for a single hub should be about 200 microseconds.