Daily Maintenance
3
Maintenance
83
H
Press [ENTER].
EMPTY
DRAIN BOTTLE
I
Press [ENTER].
RESET DRAIN
COUNTER
J
Press [MENU] to go back to the original screen.
WARNING
Never place discharged uid or ink near an open ame.
Doing so may cause a re.
CAUTION
To store discharged uid temporarily, place it in the included drain bottle
or in a durable sealed container such as a metal can or polyethylene tank,
and cap the container tightly.
Any spillage or vapor leakage may cause a re, an odor, or physical distress.
Dispose of discharged uid properly, in accordance with the laws in effect in your locale.
Discharged uid is ammable and contains toxic ingredients. Never attempt to incinerate discharged uid
or discard it with ordinary trash. Also, do not dispose of it in sewer systems, rivers, or streams. Doing so may
have an adverse impact on the environment.
If It Is Not Possible to Check the Amount of Discharged Fluid in the Drain Bottle
Sometimes, ink axes to the inside of the drain bottle, which makes it dicult to check the amount of dis-
charged uid. In this situation, clean the inside of the drain bottle by using one of the following procedures.
Procedure A
Scrape the inside of the drain bottle clean using one of the included cleaning sticks.
Dispose of used cleaning sticks. They cannot be used for any other cleaning.
If this method is not eective, perform procedure B.
Procedure B (when procedure A is not effective)
A
Remove the drain bottle, which you will clean, from the machine.
B
Attach another drain bottle (included) to the machine.
C
When discarding the liquid from the removed drain bottle, leave about 2 to 3 cm (0.8
to 1.2 inches) of discharged uid in the bottom of the bottle.
D
Securely cap the drain bottle.
E
Gently shake the drain bottle to wet the inside of the bottle with the discharged uid.
Tilt the drain bottle to make the entirety of the inside of the bottle wet.
F
Stand the bottle upright and leave it for 1 to 2 hours.