22
Parameter List
■
System Parameter [UTILITY]
→
[(Page1) F1 (SYSTEM)]
Parameter name Display Value,
Initial value
Analog Input Phantom Switch ANALOG INPUT
Off
, On
External Level Meter Display Section
DISPLAY SECTION
Off
, ANALOG INPUT 1-16, R-BUS/COAX/OPT IN,
AUX1-8/DIR1-8, ANALOG OUTPUT, R-BUS/COAX/OPT OUT
Meter Position METER POSITION
Pre
, Post
MB-24 Time Display TIME DISPLAY MEASURE/BEAT,
TIME CODE
, CLOCK/SCENE
MB-24 Meter Scale METER SCALE
X1
, X1/2
IDE Drive IDE DRIVE
Off
, On
SCSI Self ID SCSI SELF ID 0–
7
VGA Out VGA OUT Off,
On
Refresh Rate REFRESH RATE
60 Hz
, 66Hz, 70Hz, 75Hz
Holizontal Position H.POSITION -5–0–+5
Vertical Position V.POSITION When “REFRESH RATE” is 60 Hz: -22–
0
–+22
When “REFRESH RATE” is 66 Hz: -15–
0
–+16
When “REFRESH RATE” is 70 Hz: -37–
0
–+37
When “REFRESH RATE” is 75 Hz: -11–
0
–+11
Operation Target OPERATION TARGET
LCD
, VGA
PS/2 Mouse PS/2 MOUSE Off,
On
Pointer Speed POINTER SPEED 1, 2,
3
, 4, 5
PS/2 Keyboard PS/2 KEYBOARD
Off
, On
Mouse Button Swap Switch MOUSE BUTTON SWAP Sw.
Off
, On
Keyboard Type KEYBOARD TYPE
101/104
, 106/109
■
Global Parameter [UTILITY]
→
[(Page1) F2 (GLOBAL)]
Parameter name Display Value,
Initial value
Input Peak Level INPUT PEAK LEVEL 0 dB, -3 dB,
-6 dB
Foot Switch Assign FOOT SWITCH ASSIGN
Play/Stop
, Record, TapMarker, Next, Previous, GPI
CD Digital Recording CD DIGITAL REC
Off
, On
Shift Lock SHIFT LOCK
Off
, On, Once
Switching Time SWITCHING TIME 0.3–
0.5
–2.0 sec
Knob/Fader Assign Switch KNOB/FDR ASSIGN Sw
Knob
, Fader
Previous/Next Switch PREVIOUS/NEXT Sw
PHRASE
, MARKER
Locator/Scene Type LOCATOR/SCENE TYPE Safe,
Quick
Numerics Type NUMERICS TYPE
Up
, Down
Return to Locate Switch RETURN TO LOCATE Sw Off,
On
Edit Point Switch Type EDIT POINT Sw TYPE
OVERWRITE
, Same as LOCATOR
Undo Message UNDO MESSAGE Off,
On
Edit Message EDIT MESSAGE Off,
On
Pan Knob Auto Display PAN KNOB AUTO Disp
Off
, CH VIEW
Parameter Knob Auto Display PRM KNOB AUTO Disp Off,
CH VIEW
AUX Knob Auto Display AUX KNOB AUTO Disp
Off
, CH VIEW
Date/Remain Switch DATE/REMAIN Sw
Date
, Remain
Remaining Display Type REMAIN DISP TYPE
Time
, CapaMB, Capa %, Event
■
Project Parameter [UTILITY]
→
[(Page1) F3 (Proj)]
Parameter name Display Value,
Initial value
Master Clock MASTER CLOCK
INT
, R-BUS1, R-BUS2, COAXIAL IN, OPTICAL IN, WORD CLOCK,
EXT TIME CODE (Sync=MIDI IN, R-BUS1, R-BUS2, SMPTE IN)
Dither DITHER
Off
, 24bit, 23bit, ... , 8bit
Digital Copy Protect DIGITAL COPY PROTECT
Off
, On
R-BUS2 COAXIAL Select R-BUS2 COAXIAL Sel R-BUS2-1/2, 5/6,
COAX, R-BUS2-1/2
, COAX, R-BUS2-5/6,
R-BUS2 OPTICAL Select R-BUS2 OPTICAL Sel R-BUS2-3/4, 7/8,
OPTI, R-BUS2-3/4
, OPTI R-BUS2-7/8,
Display Offset Time DISPLAY OFFSET TIME
00:00:00:00.00
–23:59:59:29.99 (*)
Time Display Format TIME DISPLAY FORMAT
ABS
, REL
Peak Hold Switch PEAK HOLD Sw
Off
, On
* The settable value for Offset will change slightly depending on the MTC type.
2480v2_app_e.book 22 ページ 2006年2月7日 火曜日 午後3時33分