Page - 34 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Switches and pilot lamps of fire fighting superstructure in the cabin
A2CP cabin pump control panel
H17 warning lamp: indicates low battery charging of pump
engine
H57 warning lamp: indicates low oil pressure of pump engine
H186 multiple warning lamp: it is blinking together with an active
warning lamp
S3 switch: manual control of the priming pump
S9- switch: manual throttle decreasement
S9+ switch: manual throttle increasement
S11 switch: water tank suction valve
S14/1 switch: 3% foam proportioning rate
S14/3 switch: 8% foam proportioning rate
S17 switch: water tank pump fill valve / recirculation
S18 switch: preselection of foam compound tank suction valve
S19 switch: undertruck nozzles
S44 switch: left bottom regulated discharge valve */**
S45 switch: right bottom regulated discharge valve */**
S54 switch: manual / automatic pump control
"OFF" position -> automatic mode
"ON" position -> manual mode; the integrated pilot
lamp illuminates
S69 switch: drainage of pump system
S178 switch: deluge system
Note: The windscreen and side windows will be deluged by
6 nozzles on top as long as the switch is depressed. The
switch is only active with closed cabin doors.
Depending on the water quality operate the system in
regularly intervals to clean the system from residues.
** only active with the corresponding roller shutter is open *
Note:
A LED is installed above each switch which illuminates when the
corresponding switch on this or on an external pump control panel
is engaged.
The description includes optional equipment which is possibly not
installed on your vehicle.
Technical Description
8%
3%
8%
3%
S178
S14/3
S11 S9+
H186 S9-
S19
H57
S69
H17
S17
S54
A2CP
S3
S44
S45
S14/1
S18