Page - 61 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Air Crash Mode
S219
S292
S81f
S291
S218
S81s
19
H94
Bumper turret RM 15 C oscillator operation *
The bumper turret is equipped with an oscillating mode, which
means the turret moves automatically within a preprogrammed
area.
- Operate the bumper turret as mentioned in the
"Bumper turret operation with water" or
"Bumper turret operation with foam" chapter.
- Press "START"-switch (S218).
The bumper turret moves automatically to the preprogrammed
"attack position".
The position LED (H94) illuminates.
- Move the turret to the desired oscillation center.
- Start the oscillating operation:
Press switch (S291).
The pilot lamp in switch (S291) illuminates.
The turret moves automatically according to the prepro-
grammed oscillation area and velocity.
- The oscillation center can be adjusted by using joystick (19).
- To finish the oscillation mode press "START"-switch (S218);
continue with normal turret operation
or
press "STOP"-switch (S219).
The turret moves to it's transport position.
Programming the oscillation working area and velocity:
- Adjust oscillation working area:
Start the oscillation mode as described above.
Keep the turret's discharge valve closed.
Move the joystick (19) to desired direction and value corre-
sponding to the oscillation area, then press switch (S292).
Moving the joystick to the left -> the horizontal oscillation distance decreases.
Moving the joystick to the right -> the horizontal oscillation distance increases.
Moving the joystick forward -> the vertical oscillation distance decreases.
Moving the joystick backward -> the vertical oscillation distance increases.
Press switch (S81s) to increase or (S81f) to decrease the
oscillating velocity, then press switch (S292).
Press switch (S291) and (S292) simultaneously to save the
oscillation working area and velocity.