EasyManua.ls Logo

Rosenbauer FLF 15000 PANTHER - Emergency Operation (Electric Failure)

Rosenbauer FLF 15000 PANTHER
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page - 64 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Air Crash Mode
Y283
Y28 Y133
S9
S2NY126
Y61
ATTENTION !
- After an emergency operation return all pneumatic valves to the
initial position; if an emergency operation on the valve block is
activated, please refer to the "Emergency Control of Electro
Pneumatic Solenoids" chapter.
- After an emergency operation return switch (S2N) to the "0"
position.
- The system must be repaired immediately!
Emergency operation after a complete failure of the electric system *
The most important valves can be controlled pneumatically in the
cabin.
- Engage the pump:
Tilt down switch (S2N).
- Open the main air supply valve:
Turn main air supply valve (Y283) by 90
°
clockwise.
Roof turret operation
Water operation:
(Turn pneumatic valves (Y28) and (Y126) by 90
°
clockwise)
or use the emergency operation on the valve block - please
refer to the "Emergency Control of Electro Pneumatic Sole-
noids" chapter.
Foam operation:
(Turn pneumatic valves (Y28), (Y126) and (Y61) by 90
°
clockwise) or use the emergency operation on the valve block
- please refer to the "Emergency Control of Electro Pneu-
matic Solenoids" chapter.
Adjust required discharge pressure and throwing range by
using switch (S9).
Bumper turret operation
Water operation:
(Turn pneumatic valves (Y28) and (Y133) by 90
°
clockwise)
or use the emergency operation on the valve block - please
refer to the "Emergency Control of Electro Pneumatic Sole-
noids" chapter.
Foam operation:
(Turn pneumatic valves (Y28), (Y133) and (Y61) by 90
°
clockwise) or use the emergency operation on the valve block
- please refer to the "Emergency Control of Electro Pneu-
matic Solenoids" chapter.
Adjust required discharge pressure and throwing range by
using switch (S9).
* optional equipment