Page - 65 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Y197
Y283
Y28
Y190 S9
S2N
Y61 Y145
Air Crash Mode
ATTENTION !
- After an emergency operation return all pneumatic valves to the
initial position; if an emergency operation on the valve block is
activated, please refer to the "Emergency Control of Electro
Pneumatic Solenoids" chapter.
- After an emergency operation return switch (S2N) to the "0"
position.
- The system must be repaired immediately!
Emergency operation after a complete failure of the electric system *
The most important valves can be controlled pneumatically in the
cabin.
Undertruck nozzles operation
- Engage the pump:
◊
Tilt down switch (S2N).
- Open the main air supply valve:
◊
Turn main air supply valve (Y283) by 90
°
clockwise.
- Undertruck nozzles - water operation:
◊
(Turn pneumatic valves (Y28) and (Y145) by 90
°
clockwise)
or use the emergency operation on the valve block - please
refer to the "Emergency Control of Electro Pneumatic Sole-
noids" chapter.
- Undertruck nozzles - foam operation:
◊
(Turn pneumatic valves (Y28), (Y145) and (Y61) by 90
°
clockwise) or use the emergency operation on the valve block
- please refer to the "Emergency Control of Electro Pneu-
matic Solenoids" chapter.
- Adjust required discharge pressure and throwing range by
using switch (S9).
Dry powder rapid intervention system operation
- Open the main air supply valve:
◊
Turn main air supply valve (Y283) by 90
°
clockwise.
- Release the control pressure:
◊
Turn pneumatic valve (Y190) by 90
°
clockwise.
- Open the dry powder discharge valve:
◊
Turn pneumatic valve (Y197) by 90
°
clockwise or use the
emergency operation on the dry powder valve block - please
refer to the dry powder manufacturer's operation manual.
* optional equipment