FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Pump Panel Operation
Hydrant Operation / Supply Operation
- Shift pump system to manual mode:
Please refer to the "Manual Pump Operation" chapter.
- Connect pressure hoses to the left and/or right pressure outlets.
- Connect the supply hoses to the drafting connection (J15) (use
a collector piece if required).
- Open drafting valve:
Press switch (S12).
- Open at least one discharge valve to pull down the pressure
peaks.
- Open the hydrant valve slowly.
- When the water has reached the pump, it can be engaged:
Please refer to the "Engaging the Pump" chapter.
- Open further discharge valve(s) slowly.
- Adjust required discharge pressure:
Press switch (S9+) to increase the pump speed.
Press switch (S9-) to decrease the pump speed.
Note:
For more information please refer to the "Handline Operation"
chapter.
ATTENTION !
The pressure indicated at the manometer (P28) must not exceed
16 bar !
The pressure indicated at the manovacuummeter (P30) must not
drop below 2 bar, otherwise the supply hose will collapse and
restrict water flow.
The priming pump must not be engaged !
Before connecting a hose to the hydrant open the hydrant valve to
allow discharge, until clean water flows out of the hydrant.
For foam operation, it is necessary to feed water into the water tank
and operate the pump in tank suction mode otherwise the working
principle of the normal pressure foam proportioner is impaired by
intake pressure, the foam quality is poor and water would come
into the foam compound tank. Neglecting this warning can result
in damage of the foam compound tank.
J15
3%
8%
S9-
P28
S9+
S12
P30