Page - 74 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
ATTENTION !
Uncouple suction hoses before releasing pressure of rising fire
mains - max. permissible pressure for suction hoses is 3 bar.
CAUTION !
Release pressure before disconnecting a hose!
Pump Panel Operation
Disengaging the Pump System
- Reduce engine speed to idle:
Press switch (S9-) until the pump egine idles.
- If open, close the foam compound tank suction valve:
Check, if the pilot lamp in switch (S18) in the cabin or (S6)
on an external control panel illuminates, press correspond-
ing switch.
- If open, close the water tank suction valve:
Check, if the pilot lamp in switch (S11) illuminates, press
switch (S11).
- After foam operation the pump has to be flushed:
Please refer to chapter "Flushing after Foam Operation".
- Disengage the pump:
Please refer to the "Engaging the Pump" chapter.
- Shift pump system to manual mode to prohibit automatic cycles:
Please refer to the "Manual Pump Operation" chapter.
- Uncouple the pressure and suction hoses.
- Drain the entire pump system:
Please refer to the "Operation in Cold Climates" chapter in
this manual.
- Drying the priming pump:
Please refer to the "Operation in Cold Climates" chapter.
- Close all drain valves, pressure outlets, etc. again.
- Prepare the pump system for the next use.
8%
3%
S9- S11
S18
3%
8%
S9- S11
S6