EasyManua.ls Logo

Rosenbauer FLF 15000 PANTHER - Hose Reel Operation Modes

Rosenbauer FLF 15000 PANTHER
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page - 77 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Rapid Intervention System
CAUTION !
Before opening a handline discharge valve make sure that the
nozzles are held tightly - danger of water hammer effect!
Release pressure before disconnecting hose!
Twin agent rapid intervention system
Operation with water
- Operate the pump as mentioned in the
"Manual Pump Operation" or
"Tank Suction Operation" or
"Drafting Operation from Open Water Source" or
"Hydrant / Supply Operation" pump panel operation chapter.
Foam operation
- Operate the pump as mentioned in the
"Foam Operation" pump panel operation chapter.
Provide nozzle with the foam extension (J98). *
- Release hose reel brake (Z102).
- Remove nozzle (J99) from stowage, pull out length of hose
desired and lock brake (Z102) again.
- Open the left hose reel discharge valve:
Press switch (S21).
Note:
For best foam quality, operate pumping installation with pressure
more than 6 bar!
The left hose reel discharge valve can be operated on the left
external pump control panel as well as on the cabin's pump control
panel. *
S21 Z102