Filling the Water Tank
Filling the Water Tank via the Pump
- Operate the pump as mentioned in the
"Drafting Operation from Open Water Source" or
"Hydrant / Supply Operation" chapter.
- Open the water tank pump fill valve:
Press switch (S17).
- Observe water tank level gauge (P1).
The pilot lamp (H11) illuminates as long as the water tank
content is less than one third.
- When the water tank is full, reduce pump speed and close the fill
valve.
Press switch (S17) again.
Note:
The procedure described above can be carried out on the left as
well as on the right hand sides. *
The water tank pump fill valve will be closed automatically as soon
as a discharge valve is opened.
ATTENTION !
Before filling the water tank, the drain valve must be closed!
The maximum fill pressure is 5 bar!
By opening the tank fill valve, it is possible to run the system in "By-
Pass mode" to prevent the system from overheating. Therefore,
open the tank suction and the tank pump fill valves.
Condition: No foam compound in the pump.
Please refer to the "Stand-By Operation" air crash mode chapter.
3%
8%
H11 P1
S17