Page - 84 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Filling the foam compound tank with the electric foam compound
pump
- Connect drafting connection (J66) of the foam compound pump
to the external foam compound container.
- Turn three-way ball valve (J60) to tank fill mode "inside"
position.
- Open the external foam compound container supply valve.
- Turn switch (S168) to the "left" position.
◊
Turn switch (S168) to the left until pump is turning then
release switch (S168).
◊
The foam compound pump will automatically disengage,
when the tank is full.
- Observe foam compound level in the external foam compound
container!
Never run pump without foam compound!
- When the external foam compound container is empty or the
foam tank is full return switch (S168) to the "0" position and turn
three-way ball valve (J60) to the "transport" position.
- Flush the foam compound pump after each use!
◊
Please refer to the "Flushing of the electric foam compound
pump" chapter in this manual.
- Always provide connections (J51) and (J66) with blind cou-
plings.
Note:
Operate the engine with high idle speed to keep capacity of the
batteries in good condition. This should be done when electric fill
pump is engaged longer than 5 minutes.
Filling the Foam Compound Tank
ATTENTION !
Before beginning foam compound tank filling ensure that the drain
valve is closed.
The foam compound pump must be flushed after each use!
S168 J60 J66
J51