Page - 85 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Filling the Foam Compound Tank
S168 J60 J66
J51
Drainage of the foam compound tank / Intertank transfer via the
electric foam compound pump
- Connect drafting connection (J66) of the foam compound pump
to the empty external foam compound container.
- Turn three-way ball valve (J60) to tank fill mode "inside"
position.
- Open the external foam compound container fill valve.
- Turn switch (S168) to the "right" position.
Turn switch (S168) to the right until pump is turning then
operate switch (S168) in the fully right position until drain-
age / intertank trasfer is completed.
- Observe foam compound level in the foam compound tank!
Never run pump without foam compound!
- When the foam compound tank is empty or the external foam
compound container is full return switch (S168) to the "0"
position and turn three-way ball valve (J60) to the "transport"
position.
- Flush the foam compound pump after each use!
Please refer to the "Flushing of the electric foam compound
pump" chapter in this manual.
- Always provide connections (J51) and (J66) with blind cou-
plings.
Note:
Operate the engine with high idle speed to keep capacity of the
batteries in good condition. This should be done when electric fill
pump is engaged longer than 5 minutes.
Filling the Foam Compound Tank
ATTENTION !
Before beginning foam compound tank filling ensure that the drain
valve is closed.
The foam compound pump must be flushed after each use!