EasyManua.ls Logo

Rosenbauer FLF 15000 PANTHER - Flushing the Electric Foam Pump

Rosenbauer FLF 15000 PANTHER
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page - 86 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
S168 J60 J66
J51 J167s
Filling the Foam Compound Tank
Flushing of the electric foam compound pump
- Connect the foam suction hoses to the foam drafting/flushing
connection (J66) and put the opposite end into a container with
clean water.
- Connect hose to the flushing connection (J51).
- Turn three-way ball valve (J60) to tank fill mode "outside"
position.
- Turn switch (S168) to the "left" position.
Turn switch (S168) to the left until pump is turning then
release switch (S168).
- Flush pump until clean water is discharged.
- Return switch (S168) to the "0" position.
- Disconnect hoses from connections (J51) and (J66).
- Open drain valve (J167s).
- Turn three-way ball valve (J60) to the transport position!
- Always provide connections (J51) and (J66) with blind cou-
plings.
- Close drain valve (J167s).