Page - 86 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
S168 J60 J66
J51 J167s
Filling the Foam Compound Tank
Flushing of the electric foam compound pump
- Connect the foam suction hoses to the foam drafting/flushing
connection (J66) and put the opposite end into a container with
clean water.
- Connect hose to the flushing connection (J51).
- Turn three-way ball valve (J60) to tank fill mode "outside"
position.
- Turn switch (S168) to the "left" position.
◊
Turn switch (S168) to the left until pump is turning then
release switch (S168).
- Flush pump until clean water is discharged.
- Return switch (S168) to the "0" position.
- Disconnect hoses from connections (J51) and (J66).
- Open drain valve (J167s).
- Turn three-way ball valve (J60) to the transport position!
- Always provide connections (J51) and (J66) with blind cou-
plings.
- Close drain valve (J167s).