Maintenance
Flushing after Foam Operation
ATTENTION !
To ensure the pump operates without malfunctions, it is important
to flush the pump, priming pump, pipes and foam proportioner.
Flushing with the internal flushing line - automatic flushing procedure
Whenever the pump is operated with clean water as mentioned in the
"Air Crash Mode Operation" or
"Tank Suction Operation" or
"Drafting Operation from Open Water Source" chapter,
the pump system is flushed automatically.
- Shift pump system to manual mode:
Press switch (S54), the integrated pilot lamp illuminates.
- Select the maximum proportioning rate:
Press switch (S14/3), the integrated pilot lamp illuminates.
- Open all outlets (turrets, undertruck nozzles, hose reels, pres-
sure outlets).
- Increase pump pressure to approx. 5 bar.
- Carry on flushing until clean water is discharged.
- Open manometer flushing valves (J164) placed behind the
gauges on the left and right* hand sides.
- Before completion of flushing, flush the priming pump:
Reduce pump speed to idle (pump pressure below 2 bar).
Press switch (S3) for approx. 5 seconds.
- Disengage the pump engine:
Please refer to the "Starting the Pump Engine" chapter.
- Drain the entire pump system:
Please refer to the "Operation in Cold Climates" chapter.
8%
3%
S54
S14/3
S3
ATTENTION !
The Flushing procedure must be done carefully after each foam
operation, as well as after operation with seawater or mucky
water.
Drain the pump system when flushing is finished.
J164