Time Clock Source
Allows you to set the source for the Preview Overlay
Time Clock. This source can either be internally
generated, or generated from an external UMD device.
Press HOME > Setup > Personality and use the
Option knob to select Time Clock Source.
Note: An external UMD device must be set up on a Remote
port in order for the switcher to receive time clock data.
Internal switcher use the internally generated
time clock data.
UMD Input switcher use data from an external
UMD device for the time clock. You must use the
Time Clock UMD Number feature to set which UMD
Address that the time clock data should come from.
Time Clock UMD Number
Allows you to set the specic address of the UMD input
that you want to get the time clock data from.
Press HOME > Setup > Personality and use the
Option knob to select Time Clock UMD Number.
Use the Value knob to select the address, or UMD
input number, that you want to get the time clock data
from.
UltraChrome Dflt Color
Allows you to set the default color that the UltraChrome
will be set to when the keyer has been defaulted. Once
a different color is set for the UltraChrome, that new
color remains until the keyer is defaulted, or until a
different UltraChrome color is set manually.
Press HOME > Setup > Personality and use the
Option knob to select UltraChrome Color.
Use the Value knob to select the default color you
want to use for UltraChrome.
UltraChrome Dflt Mode
Allows you to set the default mode that UltraChrome
operates in. Once a different mode is set for the
UltraChrome, that mode remains until the keyer is
defaulted, or until a different UltraChrome mode is set
manually.
Press HOME > Setup > Personality and use the
Option knob to select UltraChrome Mode.
Use the Value knob to select the default mode for
UltraChrome. Refer to Chroma Key Modes for more
information on the UltraChrome modes.
UltraChrome Dflt Width
Sets whether or not the Edge Sensitivity is set to High
or Low when the chroma key is initialized.
Press HOME > Setup > Personality and use the
Option knob to select UltraChrome Edge.
On Additive Keying set to Off and the Width set
to 2 when the key is initialised.
Off Additive Keying set to On and the Width set
to 0 when the key is initialised.
Virtual Panel Enable
Allows you to specify whether users can access the
Acuity Virtual Panel hosted from the current panel. When
enabled (On) a user can connect to the control panel
from a web browser and control the panel remotely.
Press HOME > Setup > Personality and use the
Option knob to select Virtual Panel Enable.
On a user can connect to the panel remotely and
control it.
Off a user cannot connect to the panel remotely
(default).
Virtual Panel Positioner Reset
Allows you to specify whether the positioner on the
virtual panel returns to the neutral position automatically
(On), or if you have to click the positioner to have it
return to the neutral position (Off).
Press HOME > Setup > Personality and use the
Option knob to select Virt Panel Pos Reset.
On positioner returns to the neutral position after
0.5 seconds.
Off you must click on the positioner to have it
return to the neutral position.
VTR POL On-Air Display
Allows you to specify whether the current timecode or
the remaining time (for a video server) of the currently
loaded clip is displayed on the On-air line on the Preview
Overlay when VTR TC is active.
Press HOME > Setup > Personality and use the
Option knob to select VTR POL On-Air.
Current use the current timecode of the VTR, or
Video Server.
Remaining use the remaining time of the
currently loaded clip. Cannot be used for VTRs, or
Video Servers.
VTR POL Prepped Display
Allows you to specify whether the current timecode or
the remaining time (for a video server) of the currently
50 Personality Acuity Setup Manual (v9.2)