DescriptionLocationEvent
the parameter. Some selections
will not be available when you
reset the parameter.
4. Enter a value for the clip, gain,
or transparency for the key in the
Value field.
Swap the contents of one key with
another key the same or a different
area.
Switcher >
Keyer > Keyer
Swap
Key Swap
1. Click the 1st ME button and
select where the first key you
want to swap is.
2. Click the 1st Keyer button for
the first key you want to swap.
3. Click the 2nd ME button and
select where the second key you
want to swap is.
4. Click the 2nd Keyer button for
the second key you want to
swap.
Set or reset the keyer transition rate
of the selected area.
Switcher >
Keyer > Keyer
Trans Rate
Key Trans Rate
1. Click the ME button and select
the area that you want to
perform the event on.
2. Click the Keyer button for the
key you want to perform the
event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Enter a new transition rate, in
frames, for the key in the Value
(fr) field.
Assign a key type for a key for the
selected area.
Switcher >
Keyer > Keyer
Type
Key Type
1. Click the ME button and select
the area that you want to
perform the event on.
2. Click the Keyer button for the
key you want to perform the
event on.
3. Click a Type button to assign the
key type to the selected key.
Select whether external layer mode is
active for the selected ME.
Switcher
Installation >
ME > ME Layer
Mode
Layer Mode
1. Click the ME button for the ME
that you want to perform the
event on.
2. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
3. Click a Value button to select
whether external layer mode is
on (On) or not (Off).
Insert a loop into the custom control.Special > LoopLoop CC
DescriptionLocationEvent
Apply a mask to the selected key for
the selected ME.
Switcher >
Keyer > Mask
Force
Mask, Force
1. Click the ME button for the ME
that you want to perform the
event on.
2. Click the Keyer button for the
key you want to perform the
event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click the Value button and select
whether to force the area inside
the mask region to the
foreground (On) or not (Off).
Invert the mask of the selected key for
the selected ME.
Switcher >
Keyer > Mask
Invert
Mask, Invert
1. Click the ME button for the ME
that you want to perform the
event on.
2. Click the Keyer button for the
key you want to perform the
event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click the Value button and select
whether to invert the masked
area with the unmasked area
(On) or not (Off).
Reset the mask of the selected key for
the selected ME.
Switcher >
Keyer > Mask
Reset
Mask, Reset
1. Click the ME button for the ME
that you want to perform the
event on.
2. Click the Keyer button for the
key you want to perform the
event on.
3. Click the Action button and
select the parameter you want
to reset.
• Reset Type — turn mask
off.
• Reset Forced — turn force
off.
• Reset Inverted — turn
invert off.
• Reset X-Pos — reset
horizontal position.
• Reset Y-Pos — reset
vertical position.
• Reset Size — reset size.
• Reset Ver Edges — reset
top and bottom edges.
• Reset Hor Edges — reset
left and right edges.
68 • Custom Controls — Carbonite Operation Manual (v13.0)