EasyManua.ls Logo

Ross Carbonite Series - Custom Controls; Custom Control Events

Ross Carbonite Series
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DescriptionLocationEvent
(White), black (Black), or if there
is no border (Off).
Select whether a green (preview) tally
is shown for the selected box on the
selected MultiViewer.
MultiViewer >
Box > MV Box
Preview Tally
MultiViewer Box
Green Tally
(Preview)
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
2. Click the Box button and select
the box that you want perform
the event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click a Value button and select
whether a green tally is shown
on the selected box (On) or not
(Off).
Select whether the source label is on
or off for the selected box on the
selected MultiViewer.
MultiViewer >
Box > MV Box
Label
MultiViewer Box
Label
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
2. Click the Box button and select
the box that you want perform
the event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click a Value button and select
whether the label on the selected
box is on (On) or not (Off).
Select what source name is shown on
the label for the selected box on the
MultiViewer >
Box > MV Box
Label Mode
MultiViewer Box
Label Mode
selected MultiViewer. This event only
applies to the Carbonite eXtreme.
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
2. Click the Box button and select
the box that you want perform
the event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click a Label Mode button and
select whether the name comes
from the switcher (Switcher), the
router (Router), or both are
shown (Both).
DescriptionLocationEvent
Select the position of the source label
for the selected box on the selected
MultiViewer.
MultiViewer >
Box > MV Box
Label Position
MultiViewer Box
Label Position
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
2. Click the Box button and select
the box that you want perform
the event on.
3. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
4. Click a Value button and select
whether the label on the selected
box is at the top (Top) or bottom
(Bottom).
Select transparency for the
background behind the source labels
on the selected MultiViewer.
MultiViewer >
MV Label
Transp
MultiViewer Box
Label
Transparency
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
2. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
3. Enter the amount of
transparency in the Value (%)
field.
Select whether the MultiScreen overlay
is shown for the selected box on the
MultiViewer >
Box > MV Box
MultiViewer Box
MultiScreen
Markers selected MultiViewer. The overlay
shows what portions of the image are
MultiScreen
Marker
cropped out to fit into the output of the
MultiScreen.
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
2. Click the Box button and select
the box that you want perform
the event on.
3. Click the ME button and select
the MultiScreen you want to
view.
4. Click the Change Type button
and select whether you want to
set (Absolute) or reset (Reset)
the parameter. Some selections
will not be available when you
reset the parameter.
5. Click a Value button and select
whether the overlay is shown
(On) or not (Off).
Select whether a red (on-air) tally is
shown for the selected box on the
selected MultiViewer.
MultiViewer >
Box > MV Box
On-Air Tally
MultiViewer Box
Red Tally (On-Air)
1. Click a MultiViewer button to
select which MultiViewer you
want that you want to perform
the event on.
76 Custom Controls Carbonite Operation Manual (v13.0)

Table of Contents

Other manuals for Ross Carbonite Series

Related product manuals