UTD.187.2019.09.00_EN Operating instructions G series
4.2 - Storing
Surroundings should be suffi ciently clean, dry (relative humidity < 50%), free from excessive vibrations
(v
e
0,2 mm/s) not to damage the bearings (excessive vibration should als be guarded during transit, even
if within wider range) and at a temperature of 0 ÷ +40 °C: peaks of 10 °C above and belowe are acceptable.
The gear reducers fi lled with oil must be positioned according to the mounting position stated on name plate
during transport and storage.
Every six months rotate the shafts (some revolutions are suffi cient) to prevent damage to bearings and seal
rings.
Assuming normal surroundings and the provision of adequate protection during transit, the unit is protected
for storage up to 1 year.
For a 2 year storing period in normal surroundings it is necessary to pay attention also to following instructions:
– generously grease the seal rings, the shafts and the unpainted machined surfaces, if any, and periodically
check the conservation state of the protective anti-rust oil;
– completely fi ll the gear reducers with lubrication oil and the specifi ed level before commissioning.
For storages longer than 2 years or in aggressive surroundings or outdoors, consult Rossi.
MR CI, MR C2I
MR ICI

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rossi G Series and is the answer not in the manual?

Rossi G Series Specifications

General IconGeneral
BrandRossi
ModelG Series
CategoryEngine
LanguageEnglish

Related product manuals