INSTRUCTION, USE AND
MAINTENANCE MANUAL
19.2 “Zero mandrel” setting
When the following symbols are shown on the display
screens D1 and D2 (see Par. 19):
use / keys to select calibration. The fol-
lowing symbols will be shown on D1 and D2 display
screens (display D2 must scroll up until number 2):
Press key to confirm “piezo” calibration pro-
cedure selection; the following symbols will be shown
on D1 and D2 display screens:
Lower the cover unit and press key to start the
spin for mandrel reset without having fitted any part.
If after wheel spin, the following symbols will be shown
on display screens D1 and D2:
the calibration has been completed.
19.3 Weight measurement sensors calibra-
tion
ASSEMBLE A BALANCED WHEEL
ON THE SPINDLE AND PERFORM
THE SPINDLE “ZERO” CALIBRA-
TION PROCEDURE DESCRIBED IN
PAR. 19.3 (WITH WHEEL MOUNT-
ED).
When the following symbols will be shown displays
D1 and D2
press keys or until value 3 appears
on display D2:
Press key . The following symbols will be shown
on D1 and D2 display screens:
Take the pliers of the automatic distance/diameter
caliper and bring it to the rim edge
Wait for a few seconds and the distance in mm will be
displayed:
DYN LEDs will be flashing as well.