GB
Page 42 of 52
INSTRUCTION, USE AND
MAINTENANCE MANUAL
20.0 USER’S SETTING AND CUSTOMIZA-
TIONS
From program starting page, press keys and
at the same time; the following symbols will be
shown on D1 and D2 display screens:
Enter password , , , ; the
following symbols will be shown on D1 and D2 display
screens:
Use keys / to select the PARAMETERS
setting (P stands for Parameters). These symbols will
be shown on D1 and D2 displays:
Press key to confirm. The following symbols
will be shown on D1 and D2 display screens:
PARAMETER
NUMBER
At first
it flashes
(it can be scrolled)
PARAMETER
VALUE
At first it
does NOT flash
The D1 display screen on the left shows a parameter
number, while the corresponding parameter value is
shown on D2 display screen on the right side. The
number on D1 display is flashing.
To scroll parameters from 1 to 24, press keys
/ .
To edit a parameter value, press key first to
move the “flashing” on D2 right display, then press
keys / .
To move again the “flashing” on D1 display screen on
the left side, press again.
A special setting is connected to each parameter, as
described in the following paragraphs. Modifying the
ones requiring it and at the end press key to quit,
press it several times to return to the starting page.
1297-M043-0