INSTRUCTION, USE AND
MAINTENANCE MANUAL
9.3.4 Fitting of professional external data
gauge (optional)
1. Introduce the 4 screws (Fig. 11 ref. 1) to the gauge
bracket (Fig. 11 ref. 2) and screw them to the
threaded rivets placed on the rear side of the frame.
Lock the gauge arm (Fig. 11 ref. 3) to the bracket
(Fig. 11 ref. 2) using the 2 screws (Fig. 11 ref. 4)
and the washers (Fig. 11 ref. 5). Lock the screws
(Fig. 11 ref. 4) with the nuts (Fig. 11 ref. 6) so
that the shaft and the gauge arm are levelled out
(see Fig. 12).
1
2
3
4
5
5
6
Fig. 11
2. Also make sure the gauge tip (Fig. 12 ref. 1) is
positioned at the centre of the mandrel.
1
Fig. 12
3. Connect connector (Fig. 13 ref. 1) of the cable com-
ing from inside the machine to connector (Fig. 13
ref. 2) of the cable coming from the gauge arm. Fit
the section of the cable with the connectors inside
the arm (Fig. 13 ref. 3).
4. Fasten the cable with clamps.
5. Enable the external data gauge and carry out the
device's calibration.
1
2
3
Fig. 13
9.3.5 Monitor fitting
1. Unscrew the nuts (Fig. 14 ref. 1) and the washers
(Fig. 14 ref. 2) from the screws (Fig. 14 ref. 3).
Fit the support tube (Fig. 14 ref. 4) rotated
through 90°. Then screw the previously unscrewed
nuts and washers again.
3
2
1
1
2
2
3
4
5
Fig. 14
DURING THIS OPERATION PAY
PARTICULAR ATTENTION TO THE
POWER SUPPLY/SIGNAL CABLE
OF THE MONITOR (FIG. 14 REF. 5)
IN ORDER NOT TO DAMAGE IT.