INSTRUCTION, USE AND
MAINTENANCE MANUAL
14.2.1 Mandrel “0” (zero) calibration
Press the button (Fig. 45 ref. 1) to display the
following screen page on the monitor:
After making sure that the spindle is unloaded (no
wheel or mounted accessories), press the button
and close the guard. The mandrel will rotate
for a few minutes until you see the screen below:
At this point the machine has all its measuring fields.
Press button
to return to calibrations screen
page.
14.2.2 Weight measurement sensors calibra-
tion
ASSEMBLE A BALANCED WHEEL
ON THE SPINDLE AND PER-
FORM THE SPINDLE “0” (ZERO)
CALIBRATION PROCEDURE DE-
SCRIBED IN PAR. 14.2.1 (WITH
WHEEL MOUNTED).
- Press the button
(Fig. 45 ref. 2) to display
the following screen page on the monitor:
- Set the size of the rim on the mandrel using the
distance-diameter caliper arm.
- Set the rim width using one of the following calipers:
• Manual caliper (equipped with the machine)
• GAR305 (if present)
• GAR307
- Press button
and close the guard to the per-
form the 1st spin of the wheel without weights.
- At the end, on the monitor will appear the following
screen, saying that you should apply a weight of 100
g to the "12 o'clock" outer rim.
APPLY THE WEIGHT AT A POINT
IN WHICH BOTH SIDES OF THE
RIM THERE IS THE POSSIBILITY
OF APPLYING A CLIP WEIGHT OF
100 g.
1297-M008-8