33
8. Cleaning
•
Only clean the lift when not loaded (without
vehicle).
•
Clean main lift, lifting table and all work areas
daily. In doing so, always keep all post lift
components clean.
If the lift is in a particularly dirty environ-
ment, clean accordingly more frequently.
•
Do not use abrasive cleaning materials on lift
parts and covers. Use lint-free cloth.
•
Do not use compressors or high pressure
cleaners for cleaning work.
•
Always consult a maintenance contractor if you
identify a hazard.
•
Prior to maintenance make sure that ttings and
xtures are free of oil, lubricants, and cleaning
materials.
•
Cables (running steel cable) must be regularly
lubricated with a suitable lubricant, from
example from Duotac, CRC or Mobil (Mobilarma
798).
This can signicantly increase the service life of
the cable. Lubricant can be applied by spraying,
dipping, or brushing.
Do not clean cable with water.
Make sure that steel cable is properly lu-
bricated.
Lubricant is applied to the steel cables when
manufactured .this lubricant is depleted when
the cables is in service.And various nocuous
matters will stick to the surface of the cables.
These will cause abrasion between cables
and sheaves, and rusting of the cables. It is
important to clean and replace Lubricant
to the cables periodically
Nameplate with details of lift model, serial
number, year of manufacture etc. For the
position of the nameplate see → Fig. 5.
The Power unit's parameters are for
reference only, the actual subject to supplier.
The min height of concrete is 200mm for
SM55LT&SM65,180mm for SM40&SM40LT
;quality of concrete min C20/25.