7
Run nut down just below impact
section of bolt. Drive anchor
into hole until nut and washer
contact base.
Drill holes using 3/4” carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
Tighten nut with Torque
wrench to 110 ft.-lbs.
(149 Nm).
Fig. 4
12K 2-Post Lift Anchor Installation Reference Guide
Anchor: Min
Concrete
Thickness
Min Edge
Distance
Min Anchor
Embedment
Installation Anchor
Torque Ft-lbs
Min Concrete PSI
Strength - For All
Standards
Concrete pad
Size If Concrete
Does Not Meet
Requirements
Maintenance
Torque
Values
SEISMIC
Hilti Kwik
Bolt III (3/4" x
5-1/2")
4-1/4"
(108mm)
3-3/8"
(86mm)
3-1/4" (83mm) 110 3000 4'x4'x6" 65 Varies by
location consult
with your
structural engineer
and manufacturer’s
representative.
Hilti HY200
(with HAS
threaded rod)
5-1/4"
(134mm)
1-3/4"
(45mm)
3-1/2" (89mm) 100 / less than 3-3/4"
edge distance use
Torque Value of 30
FT/LBS
3000 4'x4'x6" N/A
*The supplied concrete fasteners meet the criteria of the American National Standard
“Automotive Lifts - Safety Requirements for Construction, Testing, and Validation” ANSI/ALI ALCTV-2011,
and the lift owner is responsible for all charges related to any additional anchoring requirements as
specified by local codes. Contact customer service for further information at: 800.640.5438
NOTE: If more than 2 horse shoe shims are used at any of the
column anchor bolts, pack non-shrink grout under the unsupported
area of the column base. Insure shims are held tightly between the
baseplate and floor after torquing anchors.