DK00027.fm
REPAIR MANUAL
BRP-Powertrain
Effectivity: 125 MAX/125 Junior MAX/125 Mini
MAX/125 Micro MAX
Edition 2 / Rev. 0
Chapter 5
Page 13
December 01/2010
Safety
instructions
See Figure 7.
Ignition end case half
NOTES: A wooden board must have cutouts for the two dowels (1)
and the cylindrical pin (2) to form a flat base for the case
half.
If it is necessary to replace the cylindrical pin (2), it can be
removed from the hot case with a pipe wrench.
Instructions
Graphic Ignition side crankcase
Figure 7
K00014
WARNING
WARNING
Danger of serious burns and scalding!
Wear safety gloves!
Step Procedure
1 Remove case half (3) from the convection oven and drop onto a flat wood
board with the case split pane. This removes the ball bearing (4) from the
crankshaft and the balance shaft.
2 Allow both crankcase halves to cool to room temperature (20 °C).
Part Function
1 Dowels
2 Cylindrical pin
3 Case half
4 Ball bearing (crankshaft)
5 Ball bearing (balance shaft)
4
5
3
1
1
2