Section 03 787 RFI ENGINE
Subsection 04 (BOTTOM END)
A32CB7A
TYPICAL
CAUTION: Bearing should not be heated to
more than 80°C(176°F). Do not heat bearing
with direct flame or heat gun or heated oil.
Inappropriate heating procedure(s) may cause
inner seal failure.
Turn bearing(s) several times during heating
process for heating it (them) properly.
NOTE: Normally it takes approximately 10 min-
utes to heat up a bearing so in the event of replac-
ing bearing, it's recommended to start the bearing
heating process prior to removal operation. Two
bearings can be heated at the same time on one
bearing heater.
A32CB8A
1
TYPICAL
1. Bearings
Touch the inner race of the bearing with the tem-
perature indicator stick (P/N 529 035 970). Stick
will liquefy when the bearing reach the proper
temperature.
A32CB9A
TYPICAL
WARNING
Do not touch heated bearing with bare han-
dle. Wear heat resisting gloves before han-
dling the heated bearing(s).
Smear Loctite 767 (anti-seize lubricant) (P/N 293
800 070) on part of crankshaft where bearing fits.
A32CB6A
TYPICAL
smr2005-083 95