2.5) External alternator (optional extra)
General note See Fig. 7.
2.5.1) Technical data
General note NOTE: The voltage regulator is integrated in the alternator.
Output Output: Max. 600 W/DC at 6000 r.p.m.
Output Voltage Output Voltage: 14.2 V - 14.8 V.
Ambient temper-
ature range
Ambient temperature: Min. -30 °C (-22 °F)
Max. +90 °C (194 °F)
Weight See chap. 72-00-00 section: Technical data.
2.5.2) Connection
Power supply
wires
Power supply wires to external alternator (1) located on the outside of pro-
peller gear.
Positive terminal Positive terminal (2):
- M6 screw connection suitable for cable terminal acording to DIN 46225
(tightening torque 4 Nm (35 in.lb).
Grounding Via engine block.
Control wiring Control wiring (field circuit) (3):
- Via supplied standard plug (Sumitomo 6111-2568) and 6.3 x 0.8 Fasten
connectors.