INSTALLATION MANUAL
BRP-Rotax
17.3) Technical data and connection of the electric components
17.3.1) Integrated generator
See Fig. 68
Feeding wires (1) from the generator to rectifier-regulator on left side
of ignition housing (see Fig. 68).
- 2 flexible cables, 1,5 mm
2
yellow (in shielding metal braid)
- length approx. 660 mm (26 in.) starting from ignition housing
- with on each plug socket 6,3 x 0,8 to DIN 46247
NOTE: approx. 250W AC output at 5800 (r.p.m.)
For DC output in connection with rectifier-regulator
see section 17.3.2.
ge
ge
Cyl. 1
Cyl. 3
Cyl. 2
Cyl. 4
Fig. 68
02498
1
yellow
yellow
17.3.2) Rectifier-regulator
See Fig. 69/70.
- type: electronic full-wave rectifier regulator
- effective voltage: 14 ± 0,3 V (from 1000 ± 250 r.p.m.)
- current limit: max. 22 A
- max. permissible
component temperature: +80 °C (176 °F)
(measured in area (1))
- weight: see section 8.
NOTE: The performance specifications are given for optimal
cooled components. If necessary, use a separate heat
sink for the rectifier regulator.