02501
During engine stop break circuit between battery and
terminal C to avoid discharge of battery! (see Fig. 67)
NOTE: A charge-indicating lamp 3W/12V (Fig. 67, pos. (18)
may be fitted on the instrument panel.
Current:
CAUTION: The graph current over engine speed has been deter-
mined and is valid only at the following conditions.
ambient temperature:....... 20 °C (68 °F)
voltage: ............................ permanent 13,5 V
tolerance: ......................... max ± 5%
1
0
10
20
1000 2000 3000 4000 5000 6000
(A)
(1/min.)
Fig. 70
02500
17.3.3) Electronic modules
See Fig. 4 and 71.
Ambient temp. for the electronic modules (1): max. 80 °C (176 °F).
17.3.4) Ignition switches (MAG switch)
See Fig. 71, 72 and 73.
- type: two separate, suitable on-off
switches (Fig. 67, pos. (15))
- switching voltage: min. 250 V
- switching current: min. 0,5 A
Wires from the ignition switches connect
to the electronic module (see Fig. 71).