Effectivity: 912 Series
Edition 1 / Rev. 1
d04641
page 131
May 01/2009
BRP-Powertrain
INSTALLATION MANUAL
21.5) Monitoring of the intake manifold pressure
See Fig. 92.
Connection nipple (1) to measure manifold pressure:
outside dia. ø ............... 6 mm (1/4")
slip-on length . max. 17 mm (11/16")
CAUTION: Utilize the total slip-on length on all joints. Secure hose by
suitable screw clamps or crimp connection.
WARNING: Protective covering to be utilized for transport and at engine
installation only. If connection for pressure reading is not
employed it has to suitably plugged. New style compensating
tubes have plugged this connection by a screw M3.5x6 (2).
CAUTION: Flawless operation of the indicating instrument needs the
installations of a water trap between engine and instrument for
the fuel condensate.
Fig. 92
02051
1
2

Table of Contents