Effectivity: 912 Series
Edition 1 / Rev. 0
d04054
page 65
May 01/2007
BRP-Rotax
INSTALLATION MANUAL
CAUTION: The stated limit loads are valid only at utilization of min
specified thread length, and must never be exceeded.
Depth of thread 18 mm (.71 in).
Fig. 37
09148
04864
04876
Axes
x axis mm
(in.)
y axis mm
(in.)
z axis mm
(in.)
-300
(-11.81 in)
-30
(-1.18 in)
-14
(-0.55 in)
-300
(-11.81 in)
-30
(-1.18 in)
-14
(-0.55 in)
attachment
points
attachment points
max. allowable forces (limit
load) in (N) in x, y and z
axis
2 000
max. allowable bending
moment (limit load) in (Nm)
in x, y and z axis
50
min. length of thread
engagement (mm)
15 (0.59 in)
12.12)Data for optional components of cooling system
- overflow bottle
See Fig. 37.