Rotax 912 ULS 3 - Connections for Bowden-Cable Actuation and Limit Load

Rotax 912 ULS 3
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page 94
May 01/2007
Effectivity: 912 Series
Edition 1 / Rev. 0
d04057
INSTALLATION MANUAL
BRP-Rotax
15.2) Connections for Bowden-cable actuation and limit load.
See Fig. 2, 3, 4, 60 and 61.
- centre position of carburetor socket (P1) of the respective carburetor:
NOTE: All dimensions to point of reference (P)
- limit load on point of reference P2
CAUTION: The specified limit loads must never be exceeded.
- connection (1) for air filter or intake silencer
outside dia.: 50 mm (2 in.)
slip-on length: 12 mm (.47 in.)
- connection for throttle actuation (2)
connection on throttle lever: set screw M 5x12
tightening torque: 4 Nm (35 in.lb)
(suitable for 1,5 mm (.06 in.) steel wire)
action travel: 65 mm (2
1
/
2
")
actuating force: min. 1,5 N (.3 lb)
max. 8 N (1,8 lb)
limit load: 20 N (4,5 lb)
NOTE: Throttle opens by spring.
P2
106
P1
P1
P1
P2
P1
Fig. 60
00538
1
3
2
carburetor for x Achse y Achse z Achse
cylinder 1/3 -521 -180 25
cylinder 2/4 -553 180 25
coordinates P1 [mm]
09190
reference point P2
max. allowable forces
(limit load) in (N)
in x,y and z axis
60
max. allowable bending moments
(limit load) in (Nm)
in x,y and z axis
4
02028

Table of Contents