To check the spring force, apply a test load (F) (test weight set assy. part
no. 976995) and measure the remaining spring length VT04 (measuring
fixture part no. 976210). See Fig. 72-72.
Test load for dual valve spring configuration:
Test load (F) for inner spring 53 N (11.91 lbf)
Test load (F) for outer 133 N (29.80 lbf)
Test load for single valve spring configuration:
Single valve spring 200 N (45 lbf)
CAUTION: Replace valves shorter than the minimum length.
NOTE: The spring length should be as equal as possible on
the inlet and outlet sides (max 0.4 mm (0.016 in.) in
difference), otherwise replace the springs.
See 72-00-00 sec. 4.