75-00-00
page 18
October 01/2010
Effectivity 912/914 Series
Edition 1 / Rev. 3
d04779
BRP-Powertrain
Maintenance Manual
12010080604020 140 160
1200
1000
(
)
(°C)
800
600
400
200
0
00327
Fig. 75-15
NOTE: Grounding connection of the temp. sensor directly via
the cylinder head.
For sensor resistance, see following graph of sensor resistance
overtemperature.
deviation: max ± 10%
On assembly, tighten the temperature sensor to 10 Nm (90 in. lb).
Secure screws with LOCTITE 221.