Effectivity 914 Series
Edition 1 / Rev. 0
76-00-00
page 41
May 01/2007
d02626
BRP-Rotax
Maintenance Manual
Resistance between the connections (5) and (6):
Throttle valve open
(throttle lever pos. 115%): 2.4 to 3.2 kΩ
Throttle valve closed
(throttle lever pos. 0%): 100 to 300 Ω
◆ NOTE: Check complete operating range as shown in
the following diagram (Fig. 76-39) for linear
resistance progress.
■ CAUTION: In the event of physical damage or resistance
readings outside allowance, replace the part
without delay.
0
0,5
1
1,5
2
2,5
3
3,5
00222
openclosed
resistance (kΩ)
throttle position
Fig. 76-39