3.6) Bowden cable, rope sheave and spring for wastegate control (on the 914
Series)
See Fig. 78-13
3.6.1) Disassembly
Remove tension spring (1) with a suitable tool and cut wire (2) of the
Bowden cable.
Loosen set screw of nipple (3) and pull Bowden cable out of the cable
retainer (4).
Do not lose the pressure spring (5) 5.5/1.2/16.9. Remove spring and
store in a safe place.
Remove cotter pin (6) and pin (7) from wastegate lever (8).
Now the Bowden cable can be pulled out from the conduit.
If required, remove rope sheave (9) after removal of the allen screw
(10) M5 x 20 along with lock washer and washer.