EasyManua.ls Logo

Rotax MML-912 - Pneumatic Synchronization

Rotax MML-912
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
d02880.fm
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 912 Series
Edition 2 / Rev. 0
12-20-00
page 34
October 01/2009
10.3) Pneumatic synchronization
General note See Fig. 16 to Fig. 19.
NOTES: Perform a mechanical synchronization before attempting a
pneumatic synchronization.
Special tool The two carburetors are adjusted to equal flow rate at idling with a suitable
flow meter or vacuum gauge(s).
Connection Possible connection methods.
Graphic Option 1
Fig. 16
08652
WARNUNG
WARNING
Danger of life threatening injuries caused by the pro-
peller, rotating and stressed parts of the engine!
Always observe the engine from a safe place while it is
running.
Option 1
Step Procedure
1 Remove the compensating tube (2) from the push on angular tube (4) after re-
moving the two clamp (3).
2 Using the push on angular tube (4) and compensating tube (2) install a flexible
rubber hose (5) leading to the vacuum gauge (1).
Part Function
1 Vacuum gauge
2 Compensations tube
3 Clamp
4 Angular tube
5 Rubber hose
4
3
5
1
4
2
3
5

Table of Contents