d02880.fm
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 912 Series
Edition 2 / Rev. 0
12-20-00
page 62
October 01/2009
14.1) Check of wiring
General note
Procedure The following steps have to be carried out:
WARNUNG
WARNING
Risk of electric shock!
Switch off ignition and remove key!
WARNUNG
WARNING
Risk of Burns!
Hot engine parts!
Always allow engine to cool down to ambient tempera-
ture before start of any work.
Step Procedure
1 Inspect all cable connectors and their connections for tight fit, good contact,
corrosion or damage and replace as necessary.
2 Inspect all ground connections for corrosion and damage, replace if necessary.
3 Inspect plug connections between pick-up cable, electronic module, charging
and shorting cables for corrosion or damage and replace as required.
4 Inspect plug connections between electronic module and ignition coils for cor-
rosion or damage and replace if necessary.
5 Verify plug connections of alternator cables with rectifier-regulator and connec-
tions of all cables on rectifier-regulator for good contact, tight fit, corrosion or
damage and replace if necessary.
6 Inspect grounding cables for tight fit, corrosion or damage and replace if nec-
essary.
7 Verify shielding of cable assemblies for corrosion or damage, good ground con-
tact and tight fit, inspect the attachment of the shielding and replace if neces-
sary.
8 Inspect all 8 ignition cables to spark plug connector for corrosion or damage
and tight fit and replace if necessary.