d02879.fm
MAINTENANCE MANUAL
BRP-Powertrain
Effectivity: 912 Series
Edition 2 / Rev. 0
12-10-00
page 10
October 01/2009
Engine test run
Engine test run is necessary:
Graphic Oil level check/Replenish
Fig. 3 08524
Step Procedure
1 Operate the engine until the temperatures have stabilized for a period of 5 min
(engine oil temperature between 50 to 70 °C (122 - 160 °F).
2 Switch the engine OFF.
3 Allow the engine to cool down.
4 Check for leaks.
5 Check the oil level and top up with oil as required.
Part Function
1 Oil tank cover
2 Oil dipstick
,1
287
PD[
PLQ
1
2

Table of Contents