Use grounded sockets and a leakage current circuit breaker in humid environments.
Operate only by trained staff or supervised trainees; no one under 16.
Avoid touching the fitting or its vicinity during and after welding due to high temperatures.
Be cautious of up to 230V at terminals; check cables and avoid touching terminals during welding.
Electrofusion welding fuses pipe and fitting surfaces using heat from the fitting's coil.
Prepare pipes by cutting, chamfering, and cleaning; respect manufacturer's instructions.
Connect terminals to fitting, ensuring clean contact; yellow LED indicates connection.
The welding process is monitored for its entire duration using computed parameters.
Auto-test found system error; disconnect unit and return for repair.
Lack of electric contact or defective heater coil; check terminals and coil.
Ambient temp outside range (-5°C to +40°C) or sensor defect.
Check power connection, switch, power line, or unit for defects.
Check terminal connection, cleanliness, welding cable, or fitting for defects.