4.4 Configurable Outputs
PIN NAME FUNCTION CURRENT MAX
1, 2, 9, 10 Configurable Positive or Negative Data Outputs 2.5A*
3-8, 11-16 Positive Only Data Outputs 0.6A Continuous
(1A peak) current
per switch*
4.5 System Connector
PIN NAME FUNCTION
1 Reset Connect to 12v to reset the MCS-32
2 Standby When connected to chassis\ground, this input places the MCS-32 into a
very low power mode. All functionality is suspended.
4.6 Inputs
PIN NAME FUNCTION
1-12 Negative Inputs User Defined
13-24 Positive Inputs User Defined
4.7 CAN Bus
PIN NAME FUNCTION
1 Remote Power Output 12v Output for CAN Remotes. Protected with a 500mA resettable fuse
2 CAN 1 High
3 CAN 1 Low
4 Ground
5 CAN 2 High
6 CAN 2 Low
RSG Engineering Limited Telephone : 01543 438800 Fax : 01543 438801 Email : sales@rsg-ontop.com Web : www.rsg-ontop.com