76
PCU6.3F - Installation
Fixed 3-phase connection.
42 mm
239 mm
113 mm
OFF
1
Optional
AUX and
water sensor
connections.
See chapter 5.
2
6
4
3
4xA
A
A
A
B
2xB
ѥ WARNING
Make sure that there is no power sup-
ply to the cooker and the oven by re-
moving their fuses. Also ensure that
the cooker is switched o.
OUT-wires are always energized when
the power control unit is connected
to the electrical network. If a wire is
loose, it must be properly covered.
ATTENTION
Install the power control unit so
that it is not exposed to moisture.
Check that all cables can move freely.
If you are replacing the cooker or the
power control unit, see chapter 4
manual adjustment mode.
IN
5 x 2,5
mm2
ON
7
Do not install the power control unit
to excessive heat: See operational
ambient temperature on the power
control unit .
OUTIN
PE
N
L1
L2
L3
PE
N
L
L
L
MAX 16A
MAX 16A
MAX 16A
MICRO DISCONNECTION
225,5 mm
78 mm
60 mm
60 mm
95 mm
L1
L2
L3
OUT
IN
OUT
IN
OUT
IN
N
PE
OUT
5 x 2,5 mm2
5
IN
Phase order can be freely chosen. If only two phases
are used, connect them to the terminals L2 and L3.