1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
No reproduction or communication without the written consent of
SAGEM SA
Page A1-5
Description of power supply ports
POWER
- 48V
2A MAX
ADR-155C
5
1
9
6
F4AL250V Fuse 4A Quick fuse
low power shutdown
250V
PWRA and PWRB
"PWR" Jack type connector
1 - 48 B1
2 - 48 B1 6 OB1
3 - Reserved 7 OB1
4 - 48 B2 8 OB2
5 - 48 B2 9 OB2
Figure 1-2 – Connecting power supply ports
"PWRA"/"PWRB" power supply interface:
Input voltage : One or two Safety Extra Low Voltage (SELV) type – 48V sources
Voltage range allowed: - 36 V to - 60 V
Maximum voltage range : - 36 V to - 72 V
Power 100 VA maximum
Connector Male 9-way HE5
6
5
9
1
Pin N° Signal name
1 -48B1
6OB1
2 -48B1
7OB1
3 Reserved
8OB2
4 -48B2
9OB2
5 -48B2
NOTA : The shielding of the connector is connected to the equipment ground
"PWR" power supply interface:
Port Connecting transformer 110-240//48V 60W/
Connector Jack (core = OB1 and shield = - 48 V1).

Table of Contents