EasyManua.ls Logo

Sagem ADR 155C - Page 17

Sagem ADR 155C
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
No reproduction or communication without the written consent of
SAGEM SA
Page A1-9
"MNGT" Interface:
Port V.11 synchronous (differential) interconnection possible with other SAGEM
equipment ADR155C, FOT 155C, through serial synchronous links used in
codirectional mode at 64 kbit/s or master contra-directional mode (rate
defined by the ADR 155C)
Bit rate 64 kbit/s,
Connector Female 9-way HE5.
6
5
9
1
Pin N° Signal name Polarity Comments
1 GND Ground (no connected)
6RXPB(+)
2 RXPA (-)
Input for data received over the P interface and sampled on the
rising edge of receive clock RXCLKP (B-A)
7TXPB(+)
3 TXPA (-)
Output for data sent over the P interface on the falling edge of
transmit clock TXCLKP (B-A)
8 TXCLKPB (+)
4 TXCLKPA (-)
Output for transmit clock; in codirectional mode, the transmit clock
timing is derived from the equipment's internal timing
9 RXCLKPB (+)
5 RXCLKPA (-)
Receive clock input
*In slave contradirectional mode (coming) TXCLK signals are inputs.
Timing diagram for the "MNGT" interface in codirectional mode (64 kbit/s synchronous use):
B8 B1 B2
B8 B1 B2
RXCLKP (B-A)
RXP (B-A)
TXCLKP (B-A)
TXP (B-A)
(receive clock input)
(input for data received
over the P interface
)
(codirectional transmit
clock output)
(output for data transmitted
over P interface)

Table of Contents