EasyManua.ls Logo

Sagem ADR 155C - Page 19

Sagem ADR 155C
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
No reproduction or communication without the written consent of
SAGEM SA
Page A1-11
Pin N°
Ports
Signal name
Comments
16
GND
ground
31
1
TX(RX) 1B
Output (Input) 2 Mbit/s (hot point)
1
TX(RX) 1A
Output (input) 2 Mbit/s (cold point)
17
2
TX(RX) 2B
Output (Input) 2 Mbit/s (hot point)
32
TX(RX) 2A
Output (input) 2 Mbit/s (cold point)
2
3
TX(RX) 3B
Output (Input) 2 Mbit/s (hot point)
18
TX(RX3A
Output (input) 2 Mbit/s (cold point)
33
4
TX(RX) 4B
Output (Input) 2 Mbit/s (hot point)
3
TX(RX) 4A
Output (input) 2 Mbit/s (cold point)
19
5
TX(RX) 5B
Output (Input) 2 Mbit/s (hot point)
34
TX(RX) 5A
Output (input) 2 Mbit/s (cold point)
4
6
TX(RX) 6B
Output (Input) 2 Mbit/s (hot point)
20
TX(RX) 6A
Output (input) 2 Mbit/s (cold point)
35
7
TX(RX) 7B
Output (Input) 2 Mbit/s (hot point)
5
TX(RX) 7A
Output (input) 2 Mbit/s (cold point)
21
8
TX(RX) 8B
Output (Input) 2 Mbit/s (hot point)
36
TX(RX) 8A
Output (input) 2 Mbit/s (cold point)
6
9
TX(RX) 9B
Output (Input) 2 Mbit/s (hot point)
22
TX(RX) 9A
Output (input) 2 Mbit/s (cold point)
37
10
TX(RX) 10B
Output (Input) 2 Mbit/s (hot point)
7
TX(RX) 10A
Output (input) 2 Mbit/s (cold point)
23
11
TX(RX) 11B
Output (Input) 2 Mbit/s (hot point)
38
TX(RX) 11A
Output (input) 2 Mbit/s (cold point)
8
12
TX(RX) 12B
Output (Input) 2 Mbit/s (hot point)
24
TX(RX) 12A
Output (input) 2 Mbit/s (cold point)
39
13
TX(RX) 13B
Output (Input) 2 Mbit/s (hot point)
9
TX(RX) 13A
Output (input) 2 Mbit/s (cold point)
25
14
TX(RX) 14B
Output (Input) 2 Mbit/s (hot point)
40
TX(RX) 14A
Output (input) 2 Mbit/s (cold point)
10
15
TX(RX) 15B
Output (Input) 2 Mbit/s (hot point)
26
TX(RX) 15A
Output (input) 2 Mbit/s (cold point)
41
16
TX(RX) 16B
Output (Input) 2 Mbit/s (hot point)
11
TX(RX) 16A
Output (input) 2 Mbit/s (cold point)
27
TX(RX) 17B
Output (Input) 2 Mbit/s (hot point)
42
17
TX(RX) 17A
Output (input) 2 Mbit/s (cold point)
12
TX(RX) 18B
Output (Input) 2 Mbit/s (hot point)
28
18
TX(RX) 18A
Output (input) 2 Mbit/s (cold point)
43
TX(RX) 19B
Output (Input) 2 Mbit/s (hot point)
13
19
TX(RX) 19A
Output (input) 2 Mbit/s (cold point)
29
TX(RX) 20B
Output (Input) 2 Mbit/s (hot point)
44
20
TX(RX) 20A
Output (input) 2 Mbit/s (cold point)
14
TX(RX) 21B
Output (Input) 2 Mbit/s (hot point)
30
21
TX(RX) 21A
Output (input) 2 Mbit/s (cold point)
15
GND
Ground
NOTA : The shielding of the connector case is connected to the subrack front panel ground

Table of Contents