EasyManua.ls Logo

Sagem ADR 155C - Page 46

Sagem ADR 155C
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - OPERATION
Installation and User Guide - N56717020101
Page A2-10
No reproduction or communication without the written consent of
SAGEM SA
The following figures give typical synchronization examples according to equipment connections.
SSM = PRC
ADR155C 1
SSM = PRC
T1-C = T0 = T3 (ADR155C1)
T1-C = T0 = T3
ADR155C 2
T0 = T1-C
ADR155C 3
T0 = T1-c
2 MHz external
sync input (T3):
- Quality = PRC,
- Priority = 1.
STM-1port (T1-C):
- Quality = DNU
- Priority = 2.
2 MHz clock output
T4= T0 = T3 (ADR155C1)
Internal
synchronization
T0 = T3
STM-1port (T1-C):
- Quality = DNU
- Priority = 2.
2 MHz clock output
T4= T1-N
Synchronization
of other e
uipments
Synchronization
of other equipments
Figure 2-1 - Synchronization from the 2 MHz external sync input (T3)
SSM = SEC
ADR155C 1
SSM = SEC
T1-C = T0 = T2
ADR155C 2
ADR155C 3
T0 = T1-c
2 Mbit/s port (T2):
- Quality = PRC,
- Priority = 1.
STM-1port (T1-C):
- Quality = DNU
- Priority = 2.
2 MHz clock output
T4= T0 = T1c West
Internal
synchronization
T0 = T2
STM-1port (T1-C):
- Quality = DNU
- Priority = 2.
2 MHz clock output
T4= T1-N
Synchronization
of other e
q
uipments
Synchronization
of other equipments
or T2 (ADR155C1)
T1-C = T0 - T1-c (West)
T0 = T1-C West
NOTE : Synchronization is applied to the 2 Mbit/s port of the ADR155C which is enabled first
(local ADR155C in the example).
Figure 2-2 - Synchronization from a 2 Mbit/s port