2 - OPERATION
Installation and User Guide - N56717020101
Page A2-16
No reproduction or communication without the written consent of
SAGEM SA
Correlation of TU/VC faults
TU-AIS, LP UNEQ, LP-RDI and LP-SLM are masked by the STM1 LOS, LOF and AIS (MS-AIS)
faults, and by the AU AU-LOP, AU-AIS, UNEQ (VC4 UNEQ) and TU-LOM faults.
TU-LOP is masked by the AU SLM and TU-LOM faults.
Tu-AIS and TU-LOP faults of a not connected input are filtered.
FAULTS
FAULTS
1
TU-AIS
2
TU-LOP
3
LP UNEQ
4
LP-RDI
5
LP-SLM
6
LOS
7
AIS
1TU-AIS
2TU-LOP
3 LP UNEQ X X
4 LP-RDI X X X
5 LP-SLM X X X
Correlation of port faults
FAULTS
FAULTS
1
LOS
2
AIS
1LOS
2AIS X
Correlation of remote faults
LO-REI, LO-RDI, HO-REI and HO-RDI faults of unidirectional connection input are filtered.