Sam4S ER230 Series Electronic Cash Register AU Program Mode Programming • 83
Program 200 - PLU Price/HALO Programming
NOTE: IF Price Level in the Memory Allocation is set 2, the 2
nd
price level must be set as well.
Price of level 2 may be $0.00.
If a PLU is open, set the HALO (high amount lock out) here. If a PLU is preset set the preset price
here. If a PLU is set with gallonage status, enter the price per liter here. (Enter price per liter in tenths
of a cent, i.e. 1299 for $1.29 9/10 per liter.)
1. Switch to P Mode by press MODE function key.
2. To begin the program, enter 2 0 0, press the SBTL key.
0 SBTL 0 2
3. Select the PLU or PLUs you wish to program in one of the following ways:
• Press a PLU key on the keyboard, or
PLU
• Press the first PLU keys that are to receive the same status and Press the last PLU
keys, or
PLU PLU
• Enter up to 15 digit number of the PLU and press the PLU key, or
PLU
Enter the PLU#,
u
to 15 di
its
• Enter the number of the first PLU in a range of PLUs that are to receive the same
setting; press the PLU key. Enter the last number in the range; press the PLU key.
PLU
Enter the PLU#,
up to 15 digits
Enter the PLU#,
up to 15 digits
PLU
4. If the PLU is open, enter a HALO of up to 7 digits. If the PLU is preset, enter a preset
price. Press X/TIME key.
X/TIME
Price/HALO
If the PLU Price Level is 2, repeat this again.
X/TIME
Price/HALO
5. To program additional PLUs, repeat from step 3, or press the CASH key to finalize the
program.
CASH